Description Of 0.4KW~800Kw Three Phase AC Motor Drive

0.4KW~800Kw Three Phase AC Motor Drive is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse

 

Features Of 0.4KW~800Kw Three Phase AC Motor Drive

1).Adopts 16 bit microprocessor, sine wave PWM control

2).Automatic torque ascension and automatic sliding compensation function

3).Output frequency 0.1-400 Hz

4).8 period of speed setting and 7 period can be running the program

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA

8).The built-in serial communication interface RS-485(baud rate can reach 38400)

9).Save energy running and automatic voltage stabilizing section function (AVR)

10).Adjustable V/F curve Acceleration and automatic and deceleration function

11).Simple vector control and built-in PID control, and the simple positioning function

12).Sleep/wake up function and zero velocity keep function

 

Structure Of 0.4KW~800Kw Three Phase AC Motor Drive

0.4KW~800Kw Three Phase AC Motor Drive

Application Of 0.4KW~800Kw Three Phase AC Motor Drive

★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

★Plastic: extruder, hauling machine, decorating machine, etc.

★Pharmacy: mixer, roaster, etc.

★Woodworking: engraving machine, sander, veneer peeling lathe, etc.

★Papermaking: single type papermaking machine, etc.

★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

★Printing: cloth-washing machine, dye vat, etc.

★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

★Fan and pump: kinds of fans, blowers and pumps

0.4KW~800Kw Three Phase AC Motor Drive

 

Performance Of 0.4KW~800Kw Three Phase AC Motor Drive

Item Specification
Input Rated voltage T4 series: Three phase 380v, ±15%
Frequency  S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
Output Voltage T4 series: Three phase 0-380V
Frequency S/T2 series: Three phase 0~220v
0-400Hz
Overload ability 150% rated current for 30s; 180% rated current for 1s;
Dissipation Cooling type  Forced Cooling
Temperature protection  Heatsink temperature >85℃ trip protection against overheat
Fan control Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work
Control Control mode Open-loop vector control, V/F control
Performance Start torque Open-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed range Open-loop vector control:1:150; 
VF control:1:100
Speed control precision Open-loop vector control: ±0.2%; 
VF control:±0.5%
Function Channel of operation command Keyboard control,terminal control,communication control
Start mode Direct start, DC injection braking before start, speed tracking before start
DC injection braking Start DC injection braking, stop DC injection braking
Dynamic braking Built-in braking unit
Frequency source choice Keyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency 1Khz~12Khz,
Acc/Dec time 0.1~6000.0s or 0.01~600.00s
Signal Analog input AVI:0~10V
ACI:4~20mA 
Keyboard potentiometer input: 0~10V
Analog output AFM:0~10V or 0~20mA, Select through JP1 jumper
Digital input A total of 28 kinds of function could be selected from S0 ~S5.
Digital output 1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication Port Communication protocol Based on RS485 hardware, support standard MODBUS protocol. 
Display Functions Four digital tube display Can monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                 Humidity Less than 90%RH
condensation
Vibration Less than0.6G
Elevation 0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature -20~60℃          
Structure Defend degree IP20

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:My Lenovo v450 laptop power adapter should be bad how to match?
Hello, this is not recommended to go online to buy. The original is too expensive, generally with the domestic voltage instability may occur, so I suggest you go to the computer city to buy. Generally good quality, to about 120. The The As for the model, you can look at the output power, or you take your bad adapter to go, people see a look. The The The You can use a few years no problem, power adapter this kind of thing, online to buy the replacement is not convenient. The Hope to help you
Q:Can the four motors be tuned to 2900 rpm?
Will be affected, under normal circumstances overclocking is possible, but speed is not possible.
Q:How to view the parameters of the notebook power adapter on your computer
Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled. Notebook power adapter using the correct method] 1. Try to avoid the use of outdoor or harsh environments to prevent the adapter is exposed or damp. 2. When you are not using the adapter, please unplug the power plug. Because, for a long time the power will let the adapter has been in working condition, will affect the end of life. 3. Although the adapter is a broadband operating voltage, marked from 100V-240V can be, but if the voltage is extremely unstable in the case of use, the same will cause damage to the power adapter.
Q:Notebook plug in the power adapter lights, but can not open the machine
Put the board under the re-installed, try and then boot. Asked: This is the case of removal, with the battery can boot answer: Then put the battery on the computer, and then use the power splitter to see if you can. If not I do not know, is the computer question to ask: This can be
Q:Motor nameplate on the standard 2P, I set the number of motor pole in the inverter, is set 2 or 4 pole?
1,2P refers to the number of motor poles, so it is certainly even 2, if the inverter is set to determine the number of motor poles, please write 2P value, if 2P = 4, please write 4 3, look at the nameplate on the motor rated speed for how much, you can confirm the number of motor poles. (N = 60f / p) P: pole pairs
Q:How does the laptop's power adapter open
Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled.
Q:How to choose the inverter
Look at the motor seat size is 7.5kw it, this model of the inverter manufacturers a lot of production, and are built-in brake unit, so in the function which are the same It is important that the inverter life, stability, price comprehensive consideration Mitsubishi, Panasonic, LG, Emerson, Yaskawa, Siemens and so on
Q:90KW inverter start 90KW, 4-pole motor and 6-pole motor j What is the difference? The inverter can be used for it?
The number of poles of the motor and the inverter is not very different, the difference is the motor speed is different
Q:Laptop power adapter (no power supply, but indicator light)
With a multimeter to measure the power adapter output interface voltage, no voltage is the adapter problem; a voltage is a notebook problem, and then decide how to do it. The adapter interface is less likely to be bad, but it does not exclude motherboard interface or power control chip problems. The former 50 yuan can get, the latter need a few hundred dollars.
Q:Yaskawa inverter reported base blockade what is the reason?
This is the base block command, when the external input block command signal, the inverter will appear this code, the code appears, the motor will be free to rotate, does not affect the use.
We are a Hi-Tech enterprise establishing the networks of development, production, logistics and service extending to all over the world from Shenzhen and Dalian. Integrating the advanced technology from Europe, America, Japan and Taiwan,.We supply customers automatic and driving products with multi-functions, such as frequency inverter, servo motor and drive, soft starter, AC Choke, EMI filter, brake Units, Brake resistor etc.

1. Manufacturer Overview

Location Liaoning,China
Year Established 2001
Annual Output Value US$5 Million - US$10 Million
Main Markets North America
South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Company Certifications ISO9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port DALIAN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average