0.4KW ~400KW 50Hz/60Hz AC Motor Drive

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 pc pc
Supply Capability:
5000 pcs per month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Description Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

CMAX  frequency  inverter is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse

 

Features Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

1).Adopts 16 bit microprocessor, sine wave PWM control

2).Automatic torque ascension and automatic sliding compensation function

3).Output frequency 0.1-400 Hz

4).8 period of speed setting and 7 period can be running the program

5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment

6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration

7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA

8).The built-in serial communication interface RS-485(baud rate can reach 38400)

9).Save energy running and automatic voltage stabilizing section function (AVR)

10).Adjustable V/F curve Acceleration and automatic and deceleration function

11).Simple vector control and built-in PID control, and the simple positioning function

12).Sleep/wake up function and zero velocity keep function

 

Structure Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

03__.jpg

 

Application Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

★Plastic: extruder, hauling machine, decorating machine, etc.

★Pharmacy: mixer, roaster, etc.

★Woodworking: engraving machine, sander, veneer peeling lathe, etc.

★Papermaking: single type papermaking machine, etc.

★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

★Printing: cloth-washing machine, dye vat, etc.

★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

★Fan and pump: kinds of fans, blowers and pumps

 

Performance Of 0.4KW ~400KW 50Hz/60Hz AC Motor Drive

Item Specification
Input Rated voltage T4 series: Three phase 380v, ±15%
Frequency  S/T2 series: Three/single phase 220V, ±15%
50/60Hz  ±5%
Output Voltage T4 series: Three phase 0-380V
Frequency S/T2 series: Three phase 0~220v
0-400Hz
Overload ability 150% rated current for 30s; 180% rated current for 1s;
Dissipation Cooling type  Forced Cooling
Temperature protection  Heatsink temperature >85℃ trip protection against overheat
Fan control Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work
Control Control mode Open-loop vector control, V/F control
Performance Start torque Open-loop vector control: 0.5Hz 180%; 
VF control: 0.5Hz 150%
Speed range Open-loop vector control:1:150; 
VF control:1:100
Speed control precision Open-loop vector control: ±0.2%; 
VF control:±0.5%
Function Channel of operation command Keyboard control,terminal control,communication control
Start mode Direct start, DC injection braking before start, speed tracking before start
DC injection braking Start DC injection braking, stop DC injection braking
Dynamic braking Built-in braking unit
Frequency source choice Keyboard digital frequency setting, analog AVI setting
PID control setting, telecommunications setting
Frequency resolution Keypad setting:0.01Hz; Analog setting: 0.1%
Carrier frequency 1Khz~12Khz,
Acc/Dec time 0.1~6000.0s or 0.01~600.00s
Signal Analog input AVI:0~10V
ACI:4~20mA 
Keyboard potentiometer input: 0~10V
Analog output AFM:0~10V or 0~20mA, Select through JP1 jumper
Digital input A total of 28 kinds of function could be selected from S0 ~S5.
Digital output 1 channel open collector output(MO1-MCM)
1 channel relay output( TA-TC normally open, TB-TC normally closed;
Communication Port Communication protocol Based on RS485 hardware, support standard MODBUS protocol. 
Display Functions Four digital tube display Can monitor the operation state of frequency inverter flexibly and conveniently.
Installation                                 Humidity Less than 90%RH
condensation
Vibration Less than0.6G
Elevation 0~1000m, reduce the rated specification 10% when lift 1000m for each. 
Storage temperature -20~60℃          
Structure Defend degree IP20

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
If the frequency converter is selected according to the motor rated current, then the motor current exceeds the rated current, the inverter will become overcurrent protection In this case, that is, when the inverter began to select the amount of time to stay the lack of the same power, inverter general type than the fan pump type current capacity of a high grade If the inverter selection is no problem, then please see whether the inverter is working temperature is too high, too high will cause the electronic components to resist the decline in current. First, check the inverter to work the ambient temperature, the second Please check the inverter fan is damaged, clean down the inverter fan channel and fan to see if there is no plug
Q:Laptop power adapter bad what is the phenomenon?
Either the power is bad or the machine on the power supply module is bad to repair service
Q:What is the output voltage of the laptop power adapter?
Generally have 19V of the common friends, I was 19V
Q:How do I protect the inverter when the three-phase two-pole motor is running?
A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
Q:What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
Probably the wider range of frequency converter applications! There is a more comprehensive protection of the motor on the inverter
Q:Is the speed of the motor controlled?
Change the external conditions, you can change the motor speed: 1. Change the number of pole pairs of the motor. (Multi-pole motor use) 2. Use the frequency converter to change the frequency speed 3. Winding motor rotor series resistance speed control. 4. Slip motor is to change the slip electromagnetic speed
Q:The notebook power adapter flashes
1: Check the socket with a multimeter is normal, the supply voltage is 220V. If the utility voltage is not normal, it is recommended to replace the use of environmental testing. 2: Check with the multimeter whether the output voltage and current of the power adapter match the label. If the gap is very large, and the mains voltage is normal, you can determine the power adapter failure, need to replace the laptop power adapter. 3: If the above check is normal, remove the laptop battery, do not external adapter. Press and hold the notebook power button 5 seconds to repeat 3 times. After releasing the notebook residual charge, insert the power adapter separately, power on the test. 4: If the fault persists, check the notebook's power connector, whether the exception. Such as loose or the appearance of damage and so on. 5: the above checks are normal, basically can be a preliminary judgment is the notebook motherboard failure. Recommended repair service station.
Q:How does the laptop's power adapter open
Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled.
Q:Siemens g120 inverter torque limit what is the meaning
Torque is a strain, the inverter can not actively control the output torque size, only according to the size of the load demand torque, the output of the corresponding torque.
Q:380V 2 pole motor can use the inverter?
Special attention, variable frequency motor with the ordinary different, easy winding film damage
We are a Hi-Tech enterprise establishing the networks of development, production, logistics and service extending to all over the world from Shenzhen and Dalian. Integrating the advanced technology from Europe, America, Japan and Taiwan,.We supply customers automatic and driving products with multi-functions, such as frequency inverter, servo motor and drive, soft starter, AC Choke, EMI filter, brake Units, Brake resistor etc.

1. Manufacturer Overview

Location Liaoning,China
Year Established 2001
Annual Output Value US$5 Million - US$10 Million
Main Markets North America
South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Company Certifications ISO9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port DALIAN
Export Percentage
No.of Employees in Trade Department
Language Spoken: ENGLISH,CHINESE
b)Factory Information  
Factory Size: 5,000-10,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average