15kw Inverter Solar

Hot Products

FAQ

Is the inverter output current proportional to the output torque?
The output voltage of the inverter is proportional to the frequency, which is to keep the motor flux constant, T = KIφ so the motor output torque is proportional to the inverter current.
What is the laptop adapter
1, laptop adapter, that is, laptop charger. The traditional notebook charger can only output a single voltage to a type of notebook computer charging, the industry said that the traditional laptop power adapter for the single-band notebook charger.
There is no inverter comes with simple PLC programming function
The inverter is an AC speed control device, like DC speed control device, DC speed is to change the armature and excitation current, and it is the input AC through the internal circuit into DC, DC and then DC, the last DC AC output, this is the original 50Hz frequency AC can output other frequencies of alternating current, because the speed v is proportional to the frequency f, so you can set the frequency of the inverter to change the speed of the control motor. It does not have its own programming function. But there are servo drives, in fact, is a frequency converter, but can handle some of their own signals, usually from the servo motor on the encoder, and then control the servo motor to achieve precise control.
What is the base blockade in the drive?
Base blockade is to deal with ul or ce such a special application of security agencies means that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop circuit more harsh they will directly disconnect the power
What is the working principle of high voltage electrodes and frequency converters?
High-voltage inverter is the input power supply voltage above 3KV high-power inverter, the main voltage levels are 3000V, 3300V, 6000V, 6600V, 10000V and other voltage levels of high-voltage high-power inverter High voltage inverter from high - low - high; low - high; high - high points.
Yaskawa inverter reported base blockade what is the reason?
Yasukawa compared garbage on the signal board on the small line of poor oxidation, and get like, this is a weak signal, and safety relays connected, do not use high-grade security circuit with a small line short, Yasukawa A 1000 factory is short for a long time after the oxidation of the base blockade
Three-phase two-pole motor can be used to reduce the frequency of the inverter
If you need to be very slow, you can match a four-level motor ah, even more slowly with a reducer
Whether the inverter can control the start and stop of the horizontal monopole centrifugal pump
Hi, the inverter control is no problem. You need to select the inverter by the load characteristics of the centrifugal pump, consider: Centrifugal pump rated working current, overload capacity, parking whether there is emergency stop request. I used the inverter to control the horizontal centrifuge some time ago.